Admin / Settings
Define the safety standards and ratings available when configuring protection tiers.
Each standard (e.g. ASTM F2413, CAT 2, NFPA 70E) can be assigned to a protection tier to automatically qualify products that carry that rating. Use the classification and category fields to organize standards by product type and hazard group.
Classification
Category
Name / Short / Full Description
#
Active
Actions
footwear
Chassis
0
Non Safety Toe
ASTM F2892 is the Standard Specification for Performance Requirements for Soft Toe Protective Footwear (Non-Safety / Non-Protective Toe). According to ASTM F2892, This specification covers minimum requirements for the performance of footwear to provide protection against a variety of workplace hazards other than the toe area that can potentially result in injury
footwear
Chassis
1
Safety Toe
ASTM F2413-18 I/75 C/75 Certified 75 ft-lb impact / 2,500 lbs compression.
footwear
Electrical
EH
Electrical Hazard
Non-conductive; withstands 18,000V @ 60Hz. Electrical Hazard rated — provides secondary protection against open electrical circuits up to 600V
footwear
Electrical
CD
Conductive
Conductive (Cd) footwear dissipates static electricity much faster than SD-rated footwear and is worn in highly flammable or explosive environments, dissipating static electricity from the body, through the shoes, and into the ground. This reduces the possibility of explosives or volatile chemicals igniting from a static spark. Static dissipative and conductive footwear both conduct electricity and therefore should not be worn where electrical hazards could be present. Explosive Areas: Max resistance 0.5 MΩ.
footwear
Electrical
SD10
SD10 - Static Dissipative
SD10 (1–10 megaohms): The strictest standard, allowing the fastest rate of static dissipation. Ideal for cleanrooms, wafer manufacturing, or handling highly sensitive micro-components. Precision range: 10^6 to 10^7 Ω.
footwear
Electrical
SD35
SD35 - Static Dissipative
SD35 (1–35 megaohms): A tighter electrical tolerance than SD100. Required in environments with sensitive electronics, or areas handling explosives and munitions. Standard range: 10^6 to 3.5 x 10^7 Ω.
footwear
Electrical
SD100
SD100 - Static Dissipative
SD100 (1–100 megaohms): The most common standard. Suitable for general manufacturing, electronics assembly, or facilities where static electricity can cause minor manufacturing problems. Broad range: 10^6 to 10^8 Ω.
footwear
Fluid/Surface
SR
Slip Resistant
High-traction outsole; meets COF standards.
footwear
Slip Resistance
SRO
Coefficient - Oil
Footwear slip-resistant enough for oil-contaminated surfaces should have a coefficient of friction (COF) of at least 0.40 to 0.50
footwear
Impact
MT
Metatarsal Guard
Upper foot protection against 75 ft-lb impact.
footwear
Structural
PR
Puncture Resistant
Midsole plate resists 270 lbs of force. Midsole protection against puncture from sharp objects — meets ASTM F2413 PR requirements
footwear
Thermal
HI
Heat Insulation
Internal temp rise < 71.6°F on 302°F surface.
footwear
Thermal
CI
Cold Insulation
Internal temp drop < 18°F in 1.4°F environment.
footwear
Outsole
HRO
Heat Resistant Outsole
Outsole resists melting/cracking at 572°F.
footwear
Specialty
AL
Alcoa Dip Rated
The ALCOA cup test is a standard, accelerated laboratory method used to evaluate the resistance of refractory materials to corrosion and penetration by molten aluminum. It involves creating a refractory cup, filling it with aluminum at 1700∘ F (927∘ C), and holding it for 72 hours to simulate furnace conditions and analyze degradation
footwear
Ankle
AN
Ankle Protection
Internal/External padding; resists malleolus impact.
footwear
Height
SO
Slip-On Shoe
Slip-on standard shoe height; No laces
footwear
Height
LOW
Low-Cut Shoe
Standard shoe height; below the ankle bone.
footwear
Height
MID
Mid-Cut Boot
4" to 5" height; sits at or slightly above ankle.
footwear
Height
6IN
6-Inch Boot
A 6-inch work boot designed for ankle protection is commonly referred to as an ankle-high work boot, 6-inch tactical boot, or a mid-cut boot. These boots are designed to provide stability against rolling or twisting
footwear
Height
8IN
8-Inch Boot
A 8-inch work boot designed for ankle protection is commonly referred to as an ankle-high work boot, 8-inch tactical boot, or a mid-cut boot. These boots are designed to provide stability against rolling or twisting
footwear
Height
10IN
10-Inch Boot
Tall boot; 10" or higher (Wellington, Pull-on or Logger).
footwear
Fluid/Surface
WR
Water Resistant
Hydrophobic upper materials; resists penetration.
footwear
Fluid Surface
WP
Waterproof
Waterproof
footwear
Chemical
CR
Chemical Resistant
Materials resistant to a broad range of industrial chemicals and solvents
apparel
No Rating
No Rating
No Rating
apparel
Flame Resistant
CAT 1
CAT 1
Arc Rating 4 cal/cm² — minimum arc flash protection level
apparel
Flame Resistant
CAT 2
CAT 2
Arc Rating 8 cal/cm² — second level of arc flash protection
apparel
Flame Resistant
CAT 3
CAT 3
Arc Rating 25 cal/cm² — high-level arc flash and flame protection
apparel
Flame Resistant
CAT 4
CAT 4
Arc Rating 40 cal/cm² — maximum arc flash protection level
apparel
Electrical
NFPA 70E
NFPA 70E
Standard for Electrical Safety in the Workplace — arc flash and electrical hazard protection
apparel
Flame Resistant
NFPA 2112
NFPA 2112
Standard on Flame-Resistant Clothing for Protection of Industrial Personnel Against Short-Duration Thermal Exposures from Fire
apparel
Chemical
ASTM F1671
ASTM F1671
Standard test method for resistance of protective clothing to penetration by bloodborne pathogens
apparel
Flame Resistant
NFPA 1977
NFPA 1977
Standard on Protective Clothing and Equipment for Wildland Fire Fighting